Current Result Document :

ÇѱÛÁ¦¸ñ(Korean Title) ¹«¼±¼¾¼­³×Æ®¿öÅ© ±â¹ÝÀÇ °¡¼Óµµ ¸ÆÆĸ¦ ÀÌ¿ëÇÑ À¯ºñÄõÅͽº ÇコÄÉ¾î ¸ð´ÏÅ͸µ ½Ã½ºÅÛ
¿µ¹®Á¦¸ñ(English Title) Ubiquitous Healthcare Monitoring System using APG Signals based on Wireless Sensor Network
ÀúÀÚ(Author) Á¤»óÁß   ÀÌÈÆÀç   Á¤¿Ï¿µ   Sang-Joong Jung   Hoon-Jae Lee   Wan-Young Chung  
¿ø¹®¼ö·Ïó(Citation) VOL 13 NO. 04 PP. 0813 ~ 0820 (2009. 04)
Çѱ۳»¿ë
(Korean Abstract)
º» ³í¹®¿¡¼­´Â ¿þ¾î·¯ºí ÆÞ½º ¿Á½Ã¹ÌÅ͸¦ ÀÌ¿ëÇÏ¿© IEEE 802.15.4 ±â¹ÝÀÇ ¹«¼±¼¾¼­³×Æ®¿öÅ© ȯ°æ¿¡¼­ ÃøÁ¤¿¡ ´ëÇÑ ¿ÜºÎÀÇ ÀÚ°¢ ¾øÀÌ ÀÚÀ¯½º·¯¿î »ýÈ° ¼Ó¿¡¼­ ÃøÁ¤ °¡´ÉÇÑ À¯ºñÄõÅͽº ÇコÄÉ¾î ½Ã½ºÅÛÀ» ±¸ÇöÇÏ°íÀÚ ÇÏ¿´´Ù. ȯÀڷκÎÅÍ »ê¼ÒÆ÷È­µµ µ¥ÀÌÅ͸¦ ÃøÁ¤Çϱâ À§ÇØ ¹Ý»çÇü ÇÁ·Îºê, »ê¼ÒÆ÷È­µµ ¸ðµâ, ±×¸®°í ¹«¼±¼¾¼­³ëµå·Î ±¸¼ºµÈ ÀúÀü·Â ¿þ¾î·¯ºí ÆÞ½º ¿Á½Ã¹ÌÅ͸¦ ±¸ÇöÇÏ¿´´Ù. TinyOS ¾îÇø®ÄÉÀÌ¼Ç ±â¹ÝÀÇ ¹«¼±¼¾¼­³ëµå´Â Á¦ÀÛµÈ ÇÁ·Îºê·ÎºÎÅÍ ÃøÁ¤µÈ µ¥ÀÌÅ͸¦ ¼öÁýÇÏ¿© ¹«¼±Åë½ÅÀ» À§ÇÑ ÆÐŶÀ» ±¸¼ºÇϸç, ¹«¼±¼¾¼­³×Æ®¿öÅ©¸¦ ÅëÇØ º£À̽º½ºÅ×À̼ÇÀ¸·Î Àü¼ÛµÈ µ¥ÀÌÅÍ´Â ¼­¹ö PC¿¡¼­ÀÇ ¸ð´ÏÅ͸µ°ú µ¥ÀÌÅÍ Ã³¸® ¹× ÀúÀåÀÌ °¡´ÉÇÏ°Ô ÇÏ¿´´Ù. ¼­¹ö PC¿¡¼­´Â LabVIEW ¼ÒÇÁÆ®¿þ¾î ÇÁ·Î±×·¥À» ÅëÇØ Àü¼ÛµÈ »ê¼ÒÆ÷È­µµ µ¥ÀÌÅÍ°¡ ½Ç½Ã°£ ¸ð´ÏÅ͸µ µÇ¸ç, PPG ÆÄÇüÀÇ 2Â÷ ¹ÌºÐ󸮸¦ ÅëÇØ µ¿¸ÆÇ÷ÀÇ »óŸ¦ ÃßÁ¤ÇÒ ¼ö ÀÖ´Â °¡¼Óµµ ¸ÆÆÄ(APG)¸¦ °ËÃâÇϵµ·Ï ÇÏ¿´´Ù. ¶ÇÇÑ ½ÇÁ¦ ¿¬·É´ëº° ½ÇÇèÀ» ÅëÇØ °¡¼Óµµ ¸ÆÆÄ¿¡ ÀÇÇÑ Ç÷°ü ź¼ºµµÀÇ ¼öÄ¡¸¦ ºñ±³ºÐ¼® ÇÏ¿´´Ù.
¿µ¹®³»¿ë
(English Abstract)
This paper describes the realization of ubiquitous healthcare monitoring system using wearable pulse oximeter based on a wireless sensor network. In order to obtain information of oxygen saturation from a patient, a small size and low power consumption wearable pulse oximeter was designed. Information of oxygen saturation collected by wireless sensor node was transmitted wirelessly to a base-station for storage and display purposes via wireless sensor network. Wireless sensor nodes were programmed by TinyOS application to perform data acquisition and transmission. LabVIEW server program was designed to monitor information of oxygen saturation and process the measured PPG (Photo plethysmogram) signals to APG(Accelerated plethysmogram) signals by appling second order derivatives. PPG signals are simple and cost effective technique to measure blood volume change.
Å°¿öµå(Keyword) ¿þ¾î·¯ºí ÆÞ½º ¿Á½Ã¹ÌÅÍ   °¡¼Óµµ ¸ÆÆÄ   À¯ºñÄõÅͽº ÇコÄÉ¾î ¸ð´ÏÅ͸µ ½Ã½ºÅÛ   Ç÷°ü ź¼ºµµ  